Measurement Solutions for Biogas & Renewable Gas
Connect h2S, moisture, gas flow, and pipeline-quality verification to the actual process conditions, installation, interfaces, and lifecycle requirements across Biogas & Renewable Gas.

Measurement priorities across Biogas & Renewable Gas
Biogas & Renewable Gas facilities combine Digesters, upgrading, compression, and injection with different process, quality, environmental, and reliability objectives. The measurement system must therefore be selected around the actual stream or asset, expected range, operating conditions, installation environment, required response, and the decision the data will support.
Blue Dragon Technology reviews the application before recommending equipment. The review covers the measurement objective, process or sample conditions, utilities, hazardous-area and environmental requirements, sample handling where relevant, control-system interfaces, calibration or verification, documentation, commissioning, and lifecycle support. Product relationships on this page identify relevant starting points; they do not replace application qualification.
Measurement challenges in this industry
H2S
Match sulfur or acid-gas measurement to the sample phase, range, composition, conditioning system, response requirement, and operating decision in Biogas & Renewable Gas.
moisture
Define the gas composition, pressure basis, expected moisture or dew-point range, contaminants, sample handling, and verification method before selecting a measurement approach for Biogas & Renewable Gas.
gas flow
Confirm pipe geometry, gas composition, pressure, temperature, velocity range, installation access, flow profile, and required measurement basis for Biogas & Renewable Gas flow duties.
pipeline-quality verification
Define the measurement objective, range, process conditions, installation, verification basis, and lifecycle requirements before selecting equipment for Biogas & Renewable Gas.
Typical process areas and streams
- Digesters
- upgrading
- compression
- injection
- flare
Applications used in this industry.
Hydrogen Sulfide Measurement
Specific H2S measurement for gas treatment, product quality, process monitoring, and safe handling applications.
Explore →
Portable H2S Field Verification
Portable H2S verification, troubleshooting and temporary field measurement.
Explore →
Trace Moisture Measurement in Gases
Continuous measurement of trace moisture in industrial gases.
Explore →
Water Dew Point Measurement
Direct or calculated water dew point measurement in gas streams.
Explore →
Industrial Gas Flow Measurement
Ultrasonic gas-flow measurement for inline and insertion applications across natural gas, process gas, fuel gas, flare, vent, and high-temperature services.
Explore →
Wet / Dirty Gas Flow Measurement
Ultrasonic flow measurement in gas with liquid/solid contamination after review.
Explore →
Custody-Transfer / Fiscal Gas Metering
Fiscal/custody gas measurement only when selected configuration and calibration qualify.
Explore →Relevant measurement capabilities.
Explore the permanent Blue Dragon capability areas associated with this industry or application.
Blue Dragon BDT Flow Measurement Series
Ultrasonic gas-flow measurement instruments engineered and manufactured by Lauris Technologies, Canada, and supplied and supported by Blue Dragon Technology.
Explore series →Moisture & Dew Point Measurement Series
Online, field, and portable instruments for trace moisture, water dew point, hydrocarbon condensation temperature, gas dehydration, and gas-quality verification.
Explore series →Sulfur Analysis Series
Online analyzers for total sulfur, hydrogen sulfide, sulfur ratio, and sulfur recovery unit process monitoring.
Explore series →Instruments connected to this industry.
Available
Lauris FF1225-G Vertical-Port Insertion Ultrasonic Gas Flow Meter
Vertical-port insertion ultrasonic gas flow meter for low-velocity flare, vent, natural gas, biogas and process-gas applications where side access is limited.
View instrument
Available
Lauris FF1225-A Single-Path Inline Ultrasonic Gas Flow Meter
Single-path inline ultrasonic gas flow meter for flare gas, vent gas, associated gas, flue gas, natural gas and industrial process-gas measurement across an exceptionally wide velocity range.
View instrument
Available
Model 810H2S-P Portable Hydrogen Sulfide Tape Analyzer
Portable industrial H₂S analyzer for field verification, temporary monitoring, process troubleshooting, and sheltered laboratory support, with 1 ppb resolution, one-second analysis, and configurable ppb-to-ppm ranges.
View instrument
Available
FAS-W Online Moisture & Dew Point Analyzer
Online chilled-mirror gas-moisture analyzer with versions for water dew point, moisture concentration, or both, plus integrated absolute-pressure measurement, 4-20 mA, Modbus RTU, and alarm outputs.
View instrument
Coming Soon
Model 810H2S Online Hydrogen Sulfide Tape Analyzer
Online H₂S tape analyzer for continuous selective hydrogen sulfide monitoring in natural gas, refinery, petrochemical, LNG, fuel-gas, hydrogen, biogas, and other process-gas applications.
View instrument
Coming Soon
Model 810H2S-TS Online Hydrogen Sulfide & Total Sulfur Tape Analyzer
Online tape analyzer for selective H₂S measurement plus Total Sulfur measurement through a dedicated heated hydrogen-conversion section.
View instrument
Available
Lauris FF1225-U Single-Port Insertion Ultrasonic Gas Flow Meter
Single-port insertion ultrasonic gas flow meter for low-velocity flare gas, storage-tank vents, process gas and replacement of conventional insertion flow meters.
View instrument
Available
Lauris FF2225-A Dual-Path Inline Ultrasonic Gas Flow Meter
Dual-path inline ultrasonic gas flow meter for flare gas, natural gas, blended gas, associated gas and industrial process streams requiring greater accuracy and measurement confidence.
View instrument
Available
FAS-SW Trace Moisture & Dew Point Transmitter
Compact 4-20 mA water-dew-point transmitter for inert, aggressive, and hydrogen-containing gases, with calibrated ranges extending to -100 °C and pressure capability up to 300 bar.
View instrumentRelated industries.
Natural Gas & LNG
Measurement solutions for gas processing, sweetening, liquefaction, LNG quality, gas flow, utilities, and materials verification.
Explore →
Pipelines & Midstream
Application-focused instrumentation for Pipelines & Midstream, covering Pipeline gas quality, dew point, H2S and sulfur, flow, and portable verification across Transmission pipelines, compressor stations, meter stations, and terminals.
Explore →
Sulfur Recovery & Gas Treating
Application-focused instrumentation for Sulfur Recovery & Gas Treating, covering H2S, SO2, sulfur ratio, tail gas, and gas moisture across Amine units, Claus SRU, tail gas, and incinerator.
Explore →
Petrochemicals
Measurement systems for petrochemical feedstocks, reaction processes, fired equipment, utilities, effluent, gas flow, and material quality.
Explore →
Chemical Processing
Application-focused instrumentation for Chemical Processing, covering Trace moisture, H2S and sulfur, TOC, flow, and multipoint temperature across Reactors, columns, specialty gas systems, and utilities.
Explore →
Hydrogen & Syngas
Application-focused instrumentation for Hydrogen & Syngas, covering Ultra-trace moisture, dew point, gas flow, H2S where relevant, and temperature across Electrolysis, reforming, purification, and compression.
Explore →Industry questions.
Which measurements should be prioritized in Biogas & Renewable Gas?
Start with the operating or quality decision that needs better information. Define the process or sample, normal and upset conditions, required range, response, accuracy, interfaces, and reference basis before selecting a technology.
Can one instrument configuration cover every Biogas & Renewable Gas application?
No. Product relationships identify relevant technologies, but sample composition, process conditions, installation, range, certification, utilities, and required method can change the correct configuration.
What information should be provided for an application review?
Provide the process/unit, measurement objective, sample or equipment conditions, range, pressure and temperature, area classification, utilities, I/O requirements, documentation, project stage, and required schedule.
Can Blue Dragon support integration and commissioning?
Yes. Project scope can include application review, system boundaries, sample conditioning or mounting, interfaces, FAT/SAT, commissioning, training, spares, and lifecycle support as defined in the quotation.
Discuss your Biogas & Renewable Gas measurement requirement.
Share the process or unit, measurement objective, operating conditions, required range, project location, utilities, interfaces, documentation requirements, and schedule for your Biogas & Renewable Gas project.