- Measurement Objective
- Dual-path inline ultrasonic gas-flow measurement for flare gas, natural gas, blended gas, associated gas, and industrial process streams requiring greater accuracy, path comparison, and measurement confidence.
- Signal Outputs
- Standard transmitter outputs include Modbus, frequency or pulse, one 4-20 mA output, and HART. Up to twelve 4-20 mA outputs and two pressure or temperature analog inputs are optional.
- Data Integration
- The control-system interface should define standard-flow conditions, pulse scaling, totalizer behavior, Modbus registers, path diagnostics, alarms, pressure and temperature input handling, and DCS, PLC, SCADA, historian, or flow-computer ownership.
- Alarms & Diagnostics
- Dual-path comparison can support diagnostic review of signal strength, transit behavior, velocity agreement, contamination, flow-profile change, and input failure. Final alarms and fail-safe logic are project configured.
- Documentation
- The package may include the product sheet, approved meter and spool drawings, path and transducer records, material documents, calibration and uncertainty certificates, pressure-boundary records, wiring and I/O details, hazardous-area certificates, and commissioning records.
- Commissioning Support
- Commissioning can verify dimensions, installation, agreement between paths, acoustic signal quality, pressure and temperature inputs, output and pulse scaling, totalizer operation, communication mapping, diagnostics, and the approved uncertainty basis.
- Lifecycle Support
- Lifecycle support covers path comparison, transducers, seals, cables, transmitter and terminals, diagnostic records, retractable assemblies where supplied, calibration guidance, spare parts, troubleshooting, and repairs.