Available
H₂S Sensing Tapes
BD-H2ST-330

Blue Dragon H₂S Sensing Tape — 330 ft

Lead-acetate sensing tape for Blue Dragon 810H₂S and 810H₂S-TS online analyzers.

Consumable Overview

Controlled consumable supply for the analyzer lifecycle.

Blue Dragon H₂S Sensing Tape — 330 ft is the controlled lead-acetate sensing consumable for the Model 810H2S online hydrogen sulfide tape analyzer and Model 810H2S-TS hydrogen sulfide and total sulfur tape analyzer. Fresh treated tape provides the reaction surface used by the optical H₂S measurement system.

The 330 ft format supports extended online analyzer operation while retaining controlled tape width, chemistry, optical response and batch consistency. Batch inspection documentation is available, and the tape has a minimum 10-year shelf life when kept in its original protective packaging in a cool, dry environment.

Key Characteristics

  • 330 ft format for Blue Dragon 810H₂S and 810H₂S-TS
Technical Data

Consumable specifications and sensing characteristics.

Sensing chemistry

Detection Principle

Hydrogen sulfide reacts with the lead-acetate chemistry on the sensing substrate to form a brown-to-dark lead-sulfide (PbS) stain. The online analyzer measures the optical change on fresh tape to determine H₂S concentration. The tape sensitivity specification is 0.01 ppm H₂S; overall analyzer detection performance also depends on analyzer configuration, sample conditions, calibration and operating parameters. In the 810H2S-TS, Total Sulfur measurement is achieved through the analyzer's sulfur-conversion system before H₂S detection on the tape.

Complete Technical Data

Roll length
330 ft / 100.58 m
Tape width
0.5 in / 12.7 mm
Tape thickness
0.15 mm
Core internal diameter
25.4 mm
Reel / flange diameter
135 mm
Detection chemistry
Lead-acetate treated sensing substrate
Lead-acetate treatment
9.5–10.5% by volume
Treated substrate loading
≥22 g/m²
Substrate composition
89.5–90.5% by volume cotton fibre (paper tape)
Tensile strength
0.58 kg/mm²
Tape sensitivity
0.01 ppm H₂S
Batch-to-batch response tolerance
≤5%
Optical response
Brown to dark lead-sulfide (PbS) stain on a white background
Winding direction
Clockwise or counter-clockwise, according to reel configuration
Shelf life
Minimum 10 years in original protective packaging under specified storage conditions
Storage
Store in original protective packaging in a cool, dry environment
Batch documentation
Batch inspection report available
Primary Blue Dragon analyzers
Model 810H2S; Model 810H2S-TS
Primary Analyzer Compatibility

Designed for Blue Dragon analyzers.

Analyzer compatibility shown here is controlled by the Core product relationship map so the analyzer and consumable pages remain synchronized.

Third-Party Compatibility

Compatibility & Cross-Reference

Blue Dragon analyzer applications remain the primary use. The references below identify selected third-party lead-acetate sensing-tape applications for configuration review.

Manufacturer
Reference
Application note
Galvanic
CO0329
Long-roll lead-acetate H₂S sensing-tape cross-reference, including selected ProTech903 configurations.
Envent
2000040
Current 300 ft lead-acetate H₂S sensing-tape reference for selected 330S / 331S configurations.
Envent
330133XS
Legacy / alternate 300 ft H₂S sensing-tape reference.
Thermo / Tracor / Houston Atlas
000098B
300 ft lead-acetate H₂S sensing-tape cross-reference.

Galvanic, Envent, ProTech, Thermo, Tracor, Houston Atlas, DelMar and referenced model or part numbers are trademarks or identifiers of their respective owners. Blue Dragon Technology is an independent supplier and is not affiliated with or endorsed by these manufacturers. References are provided solely for equipment compatibility and cross-reference identification. Confirm analyzer configuration and reel requirements before ordering.

Selection & Compatibility

H₂S Sensing Tape FAQ

Answers to common analyzer-fit, part-number cross-reference, roll-length, and storage questions.

Which Blue Dragon analyzers use the 330 ft H₂S sensing tape?

Blue Dragon BD-H2ST-330 is the controlled long-roll lead-acetate sensing tape for the Model 810H2S Online Hydrogen Sulfide Tape Analyzer and Model 810H2S-TS Online Hydrogen Sulfide & Total Sulfur Tape Analyzer.

Is BD-H2ST-330 compatible with Galvanic CO0329 sensing-tape applications?

BD-H2ST-330 is cross-referenced to Galvanic CO0329 for selected compatible long-roll lead-acetate sensing-tape applications, including selected ProTech903 configurations. Confirm analyzer and reel requirements before ordering.

Does BD-H2ST-330 cross-reference Envent 2000040 and 330133XS?

Yes. Envent 2000040 is a current 300 ft lead-acetate H₂S sensing-tape reference, while 330133XS is an established alternate or legacy 300 ft reference. BD-H2ST-330 is Blue Dragon’s standard long-roll format for selected compatible configurations. Confirm the analyzer and reel configuration before ordering.

Is the 330 ft tape compatible with Envent 330S and 331S analyzers?

BD-H2ST-330 is intended for selected compatible Envent 330S, 330SDS, 331S and 331SDS lead-acetate tape configurations associated with the applicable tape references. Confirm the exact analyzer configuration before ordering.

Can a 330 ft H₂S sensing tape be used where a nominal 300 ft roll is specified?

Some tape-based analyzer platforms specify nominal 300 ft rolls. BD-H2ST-330 is Blue Dragon’s standard 330 ft long-roll format and may be used where the analyzer and reel configuration are compatible. Confirm the analyzer model, tape reference and reel requirements before ordering.

Is BD-H2ST-330 cross-referenced to Thermo, Tracor or Houston Atlas 000098B?

000098B is a 300 ft lead-acetate H₂S sensing-tape cross-reference associated with Thermo, Tracor and Houston Atlas systems. BD-H2ST-330 can be considered for selected compatible long-roll configurations after confirming the analyzer and reel requirements.

What is the shelf life of the 330 ft H₂S sensing tape?

The minimum shelf life is 10 years when the tape is retained in its original protective packaging and stored in a cool, dry environment.

How should H₂S sensing tape be handled and disposed of?

H₂S sensing tape contains lead acetate. Wear protective gloves when handling the tape, prevent the material from entering drains or the environment, and dispose of tape waste in accordance with applicable regulations. Refer to the current Safety Data Sheet for complete safety information.

Technical Resources

Consumable Documents

Product sheets, safety information, quality documentation, and other controlled resources appear when available.

Product Enquiry

Confirm the consumable for your analyzer.

Provide the analyzer model and current consumable reference when requesting product information or pricing.